Wuhan Global Metal Engineering Co., Ltd
The pioneer manufacturer of heaters & sensors
Place of Origin: | China |
Brand Name: | GME |
Certification: | CE |
Model Number: | CARD |
Minimum Order Quantity: | 1 pcs |
---|---|
Price: | Negotiable |
Packaging Details: | Standard Export Packing |
Delivery Time: | 7-15days |
Payment Terms: | L/C, D/A, D/P, T/T, Western Union, MoneyGram |
Supply Ability: | 10000pcs/month |
Usage: | Hot Runner System | Theory: | Temperature Controller |
---|---|---|---|
Accuracy: | ±0.25% | Temperature Range: | 0℃-500℃(32℉~932℉) |
Control Output: | PWM Or SSR | Output Type: | Zero Cross / Phase Angle |
Working Temperature: | 0~50℃(32~122℉) | Load Capacity: | 15A,3600W @ 240Vac Per Zone |
High Light: | multi-zone temperature controller,hot runner temperature controller |
Industrial Hot Runner Temperature Controller Compatible With YUDO And DME
Main Features
(1) Independent display units, indicators and operator keypad for each zone, easy to use
(2) Dual-zone per module, low cost and saving space(3) Load current, power output can be displayed
(4) Auto/Manual/Standby function
(5) PID auto temperature control
(6) Selectable two thermocouple types (J or K)
(7) Selectable two temperature scales (℃or℉)
(8) Selectable two trigger output modes (Zero cross or phase angle)
(9) Multi diagnostic & alarm function
(10) Multi self-protect and equipment-protect function
(11) Recover parameters default easily
(12) Selectable two start modes (Soft-start or Full-speed)
Specifications
Power Supply | AC85~ 415V, 50/60HZ | Consumed Power | < 4W |
Control Mode | Auto-PID / Manual | Output Type | Zero Cross / Phase Angle |
Sensor Type | Thermocouple J or K | Measurement Range | 0~500℃(32~932℉) |
Measurement Accuracy | ±0.25% FS | Setting Range | 0~450℃(32~842℉) |
Control Accuracy | ±0.25% FS | Load Capacity | 15A,3600W @ 240Vac per zone |
Working Temperature | 0~50℃(32~122℉) | ||
Storage Temperature | -20~70℃(-4~158℉) | Switching Mode | Rocker Switch |
Working Humidity | 10~80%RH(No condensing) |
Protection Fuctions
1. Wide power supply range, AC85~415V
2. Thermocouple input protection, prevent module damaged by mis-connection
3. Thermocouple & heater inverse protection, prevent thermocouple damaged by mis-connection
4. Soft-start mode, avoid the humidity make the heater burn out
Diagnostic Function
Alarm when the followings occurred
1. Ultra-high or ultra-low Temperature
2. Thermocouple break, short or inverse
3. Thermocouple is out of its position
4. Heater break, short or overload
5. Output device is damaged
Accessories
Cables: provide 16/24 core combination hot runner cable and mold power cable, thermocouple cable or customized