    Product Details:

    Place of Origin: China
    Brand Name: GME

    Payment & Shipping Terms:

    Minimum Order Quantity: 10 pcs
    Delivery Time: 7-10 working days
    Payment Terms: T/T, Western Union
    Contact Now
    Detailed Product Description
    Section: 6x6mm Power: Customized
    Application: Hot Runner System Sheath Material: Stainless Steel
    Resistance Wire: Ni80Cr20 Insulation Material: MgO
    High Light:

    6x6mm Tubular Heater

    ,

    Hot Runner Manifolds Tubular Heater

    ,

    Square Section Tubular Heater

    Flexible Tubular Heater Square Section 6x6mm For Hot Runner Manifolds

     

    Produce Description

     

    Tubular heater is used for almost every kind of heating appliances. They are easy to form and feature highest mechanic stability and electric properties at the same time. Even though tubular heaters are technically rather mature and universal to use, there exist various new innovative solutions for many applications. Screw in tubular heaters are standardized for use in liquids like water. Finned tubular heaters are especially for air heating cabinets or tunnels. Flanged heater are easy to install, control and maintain, unique designer as your requirement. For corrosive environment, titanium material or tubular heating elements with additional sleeving are available .

     

    In contrast to traditional tubular heaters with a round section which have to be bent by machines, square tube can be fitted into any rectangular groove with simple hand tools. Moreover, the square shape results in a bigger heat emitting area of up to 80% compared with a corresponding round section. Finally, the easy manual mounting saves the usually high technical expenditure for casting-in / soldering / cementing of bent round tubular heaters.

     

     

    Specification

     

    Heat intensity Not exceeding 30Wcm2 (advisable)
    Power Depends on the dimension
    Escape of current (when cold) <=0.1mA a 242 v.
    Insulation (when cold) 5 Min Ohmis 500 Watts minimum
    Dielectric strength 1500v. 1/seg
    Working temperature 750ºC max.
    Tolerance of length +/-1.5%
    Tolerance of diameter -0.01 a -0.06 m/m
    Tolerance of cut of connection +/-15 mlm
    Power tolerance (w) 5 % - 10 %
    Cold areas Depends on length and diameter 5-25mm

     

     

    Technical Data for Flexible Manifold Tubular Heater

     

    Length 300-1550mm 400-2100mm
    Max Current 12A 15A
    Nominal Voltage Less than 230V Less than 400V
    Wattage ±10% ±10%
    Dielectric Strength 1.5HV 1.5HV
    Insulation MΩ More than 5 MΩ More than 5 MΩ
    More than 5 MΩ Less than 0.5 mA Less than 0.5 mA
    Minimum Unheated 30mm 35mm
    Terminal Pins M3 x .50mm / plain post M4 x .70mm

     

     

    Feature

     

    1. Designed and built for safety.
    2. Broad variety of sizes for different applications;
    3. Compact;
    4. Easy to maintain;
    5. Energy -saving, efficient
    6. Flexible tubular heater should be protected against damp during storing or installing to ensure the performance of the heater.
    7. In order to be sure of well-distributed load of each and groups heater should be divided before assembling.
    8. The tolerance of the resistance of each one can not exceed by 10% each other.
    9. At the beginning of the operating the electric furnace , the voltage should be increased slowly and can not be fully loaded at once. Otherwise the larger current will be resulted in the damage of heater
    10 . Heater is hard and brittle, please be careful when assembling and maintaining so as to avoid damage.
    11.When heater is damaged and need to be changed , the resistance of new heater should follow the increasing resistance. If many are damaged or resistance increased too much, all the heater should be changed.

     


    Application

     

    1. plastic processing and packaging machinery
    2. Plastic processing machinery;
    3. Water heating appliances;
    4. Packaging machineries;
    5. Heating chemical solutions;
    6. Kitchen appliances;
    7. Medical areas;
    8.extruders;
    9.foundaries;
    10.for fastening of Turbine Bolts;
    11.Soldering pots;
    12.injection blow moulding;

     


     

     