Send Message

Wuhan Global Metal Engineering Co., Ltd

                                 The pioneer manufacturer of heaters & sensors

Home ProductsTubular Heater

Flexible Industrial Tubular Heater For Hot Runner Manifold 6.6MM

Flexible Industrial Tubular Heater For Hot Runner Manifold 6.6MM

    • Flexible Industrial Tubular Heater For Hot Runner Manifold 6.6MM
    • Flexible Industrial Tubular Heater For Hot Runner Manifold 6.6MM
    • Flexible Industrial Tubular Heater For Hot Runner Manifold 6.6MM
    • Flexible Industrial Tubular Heater For Hot Runner Manifold 6.6MM
  • Flexible Industrial Tubular Heater For Hot Runner Manifold 6.6MM

    Product Details:

    Place of Origin: China
    Brand Name: GME
    Certification: ISO9001/CE

    Payment & Shipping Terms:

    Minimum Order Quantity: 10pcs
    Price: Negotiable
    Packaging Details: Carton or wooden crate or as per your request
    Delivery Time: 10 working days or above
    Payment Terms: L/C, T/T,PAYPAL
    Supply Ability: 100000pcs
    Contact Now
    Detailed Product Description
    Product Name: Diameter 6.6mm Stainless Steel Sheath Flexible Manifold Tubular Heater For Hot Runner Application: Industrial Heating Elements
    Sheath Material: Incoloy 800, SS 304, SS 321, SS 316 Voltage: Customized
    Resistance Wire: Ni80Cr20 Power: Customized
    High Light:

    thermostatic tubular heater

    ,

    tubular heater elements

    Diameter 6.6MM Stainless Steel Sheath Flexible Tubular Heater For Hot Runner Manifold

     


    Produce Description 

     

    Tubular heating elements perform exceptional heat transfer by conduction, convection or radiation to heat liquids, air, gases and surfaces. Tubular heating elements are also used for radiant heating in open air or in vacuum atmospheres.


    It is the most versatile heating appliance among all electric heating elements.In most heater assemblies, tubular element design configurations vary — round, triangular, flat press and formed.

     

    Tubular heater is used for almost every kind of heating appliances. They are easy to form and feature highest mechanic stability and electric properties at the same time. Even though tubular heaters are technically rather mature and universal to use, there exist various new innovative solutions for many applications. Screw in tubular heaters are standardized for use in liquids like water. Finned tubular heaters are especially for air heating cabinets or tunnels. Flanged heater are easy to install, control and maintain, unique designer as your requirement. For corrosive environment, titanium material or tubular heating elements with additional sleeving are available .

     

     

    Specification

     

    Heat intensity

    Not exceeding 30Wcm2 (advisable)

    Power

    Depends on the dimension

    Escape of current (when cold)

    <=0.1mA a 242 v.

    Insulation (when cold)

    5 Min Ohmis 500 Watts minimum

    Dielectric strength

    1500v. 1/seg

    Working temperature

    750ºG max.

    Tolerance of length

    +/-1.5%

    Tolerance of diameter

    -0.01 a -0.06 m/m

    Tolerance of cut of connection

    +/-15 mlm

    Power tolerance (w)

    5 % - 10 %

    Cold areas

    Depends on length and diameter 5-25mm

     

     

    Technical Data for Flexible Manifold Tubular Heater

     

    Length 300-1550mm 400-2100mm
    Max Current 12A 15A
    Nominal Voltage Less than 230V Less than 400V
    Wattage ±10% ±10%
    Dielectric Strength 1.5HV 1.5HV
    Insulation MΩ More than 5 MΩ More than 5 MΩ
    More than 5 MΩ Less than 0.5 mA Less than 0.5 mA
    Minimum Unheated 30mm 35mm
    Terminal Pins M3 x .50mm / plain post M4 x .70mm
     

     

     

    Feature

     

    1. Designed and built for safety.
    2. Broad variety of sizes for different applications;
    3. Compact;
    4. Easy to maintain;
    5. Energy -saving, efficient
    6. Flexible tubular heater should be protected against damp during storing or installing to ensure the performance of the heater.
    7. In order to be sure of well-distributed load of each and groups heater should be divided before assembling.
    8. The tolerance of the resistance of each one can not exceed by 10% each other.
    9. At the beginning of the operating the electric furnace , the voltage should be increased slowly and can not be fully loaded at once. Otherwise the larger current will be resulted in the damage of heater
    10 . Heater is hard and brittle, please be careful when assembling and maintaining so as to avoid damage.
    11.When heater is damaged and need to be changed , the resistance of new heater should follow the increasing resistance. If many are damaged or resistance increased too much, all the heater should be changed.

     


    Application

     

    1. plastic processing and packaging machinery
    2. Plastic processing machinery;
    3. Water heating appliances;
    4. Packaging machineries;
    5. Heating chemical solutions;
    6. Kitchen appliances;
    7. Medical areas;
    8.extruders;
    9.foundaries;
    10.for fastening of Turbine Bolts;
    11.Soldering pots;
    12.injection blow moulding;
     

    Contact Details
    Wuhan Global Metal Engineering Co., Ltd

    Contact Person: summy

    Tel: +8615071256252

    Send your inquiry directly to us (0 / 3000)